Fault Handling

The fault manager (ecu_fault) provides priority-based fault reporting, latching, retry policies, and degrade mode support.

Severity Levels

Level

Action

Behaviour

Info

None

Logged but no system action taken

Warning

Degrade

Reduce power, may auto-clear when condition resolves

Critical

Shutdown

Latched — requires safe shutdown sequence

Fatal

Shutdown

Immediate safe shutdown, cannot clear without reset

Degrade Mode

When a warning-level fault is active the system enters degrade mode:

  1. Maximum throttle limited to 50 %

  2. RPM limit reduced by 20 %

  3. Additional sensor monitoring enabled

  4. Telemetry sends fault notification to host

Recovery

  • Warning faults — auto-clear when the triggering condition resolves.

  • Critical faults with retry — up to 3 retry attempts (configurable via ecu_fault_set_retries()).

  • Fatal faults — require a power cycle.

Fault Log